Thermocouple temperature sensors with double ceramic tube and measuring insert
- outer ceramic C530 (diameter 26 mm) and inner ceramic C610
- base metal thermocouple type K or N
Thermocouple temperature sensors with double ceramic tube and measuring insert
Temperature sensors of the MTC1KV series are designed for applications with operating temperatures up to 1200 °C and high chemical aggressiveness of the environment. They have a double ceramic tube: the outer one made of “Lunit 20” material, the inner one made of “Lunit 73” material. They are characterised by good resistance to temperature shocks. The outer ceramic tube is not completely gas-tight, the inner one is. In combination with the thermocouple measuring insert, they provide the thermocouple with good overall protection against the negative effects of the measured atmosphere, thus increasing the sensor’s lifetime.
The measuring element is a base metal thermocouple, type K or N. The output signal of the thermocouple is a voltage, whose dependence on temperature is defined by the ČSN EN 60584-1 ed. 2 standard.
The sensor consists of a head, holding pipe, outer and inner protective ceramic tube and a measuring insert, in which one or two thermocouples can be installed. The head is equipped with a cable gland for connecting the compensation cable.
The sensor can be fitted with a temperature converter. A PR mounting flange can be used to secure the sensor at the measuring point.
Category: Thermocouple Temperature Sensors Tags: ceramic temperature sensor, type S thermocouple, thermocouple, pyrometer, thermoelectric temperature sensor, high temperature measurement, measuring insert, crematorium, base metal thermocouple, type N thermocouple, type K thermocouple